UPS2000-G-15K is used for power systems in various scenarios, including communications rooms, customer service centers, laboratories, instrument rooms, control rooms, offices, billing centers, precision control rooms, and process control centers. UPS2000-G-15K is an online double conversion and sine wave power system that delivers continuous, high-quality AC power to precision instruments. The UPS can be tower- or rack-mounted, depending on the site requirements. It supplies AC power to small computer centers, networks, communications systems, automatic control systems, and precision instruments. The UPS provides optional components, such as a power distribution unit (PDU), monitoring ports, and an SNMP card, to deliver comprehensive solutions for low- and medium-powered equipment.
Capacity
|
15kVA/13.5kW
|
20kVA/18kW
|
Model |
UPS2000-G-15KRTL |
UPS2000-G-20KRTL |
Input |
||
Input and output formats |
1 ph input /1 ph output |
|
Rated Voltage |
L-N: 220/230/240Vac |
|
Input Voltage Range |
L-N: 80-280Vac |
|
Input Frequency Range |
40-70Hz |
|
Battery Voltage |
±(192-240)Vdc |
|
Output |
||
Output Voltage |
L-N: 220/230/240Vac |
|
Output Frequency |
Tracking bypass input
(Online mode); 50/60±0.1 Hz(Battery Mode) |
|
Waveform |
Sine wave; THDv<2% |
|
Output port |
OT connect terminal |
|
System Efficiency |
Up to 95% |
|
Overload Capacity |
125% overload for 5 min;
150% overload for 1 min |
|
Environment |
||
Operating Temperature |
0℃-40℃ |
|
Storage Temperature |
-40℃-70℃ |
|
Relative Humidity |
0%-95%(No condensing)
|
|
Operating Altitude |
1000m |
|
Audible Noise |
<58dB
|
|
Others |
||
Height×Width×Depth (mm) |
130×430×685 |
|
Weight |
32kg |
|
Communication interfaces |
RS485、USB、SNMP、dry contacts |
|
Certification |
CB、CE、TLC、CQC、ECA |
For more details, please refer to Huawei Small UPS UPS2000-G Series (1-20kVA) Datasheet (PDF).
UPS2000-G-15KRTL
|
15kVA/13.5kW,support 1-phase input /
1-phase output , 3-phase input / 1-phase output and 3-phase
input / 3-phase output |
UPS2000-G-20KRTL |
20kVA/18kW,support 1-phase input / 1-phase output , 3-phase
input / 1-phase output and 3-phase input / 3-phase output |
Battery pack |
240V/7Ah battery pack |
Communication card |
|
Dry Contact Card |
provides six alarm dry
contact outputs and two dry |
Modbus Card |
Provides an RS485
networking solution for remote UPS management. |
SNMP Card |
Remotely manage the UPS
by |
Power Distribution
Component |
|
PDU |
Supports 2 units parallel
system, protects AC input and output, increases output
sockets, and implements online UPS maintenance |
STS(16A) |
switching primary loads
between two power sources |
Others |
|
Temperature Sensor |
monitoring the
temperatures of the battery packs or between batteries |
Ambient Temperature and
Humidity Sensor |
working with the SNMP
card and testing the temperature and humidity of UPS |
Rails |
configuring with rack |