Focus on Americas Market
View Quotation Cart ( 0 )
PDU3MV6L2130A | ActForNet

MPN: PDU3MV6L2130A
Category: UPS >> Surge Protection
Vendor: Tripp-Lite
Weight: 37 LB(S)
Price: US$ 637.5

-
+
Tripp Lite 3 phase Metered PDU / Power Distribution Units offer real-time local reporting of current levels in amps via set of 3 built-in digital meters. Enables visual monitoring of PDU current levels to preserve proper loading balance and prevent circuit overloads as additional equipment is added. Offers reliable rackmount multi-outlet power distribution from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.


???  8.6kW 3 phase 208V Metered Power Distribution Unit / PDU

???  Set of 3 built-in current meters continuously report load current in amps for all 3 output phases

???  Attached NEMA L21-30P (3P+N+E) 208V 3 phase input plug with 6 ft. / 1.8m cord

???  0U, 70 in. / 178cm vertical form factor supports installation in 2 or 4 post equipment racks

???  45 total 208V outlets (36 C13, 9 C19) arranged in three breakered single phase output load banks

???  Included cord retention sleeves keep vital network equipment plugged in and continuously powered

???  Toolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications (set of 2 9mm buttons pre-installed, 2 9mm and 4 6mm spare buttons included)

???  TAA Compliant

PDU TypeMetered

Output Capacity Details8.6kW (208V) total capacity 13.9A max per output phase (L1-L2, L2-L3, L3-L1), 12A max per C13 outlet

Frequency Compatibility50 / 60 Hz

Output Receptacles(36) C13, (9) C19

Output Nominal Voltage208

Overload Protection3 20A double-pole circuit breakers (1 per output phase)

PDU Input Voltage208

Recommended Electrical Service30A 208V with NEMA L21-30R outlet

Maximum Input Amps24

PDU Plug TypeNEMA L21-30P

Input Cord Length (m) 1.83

Input Phase3-Phase

Reported Load SegmentsSupports local monitoring of current for each output phase (13.8A balanced max per output load bank L1-L2, L2-L3 and L3-L1) Outlets are color coded and labelled for phase and load bank identification L1-L2 feeds black outlets L2-L3 feeds dark-gray outlets L3-L1 feeds light-gray outlets

Front Panel LCD DisplaySet of 3 digital current meters report output current per phase

Front Panel LEDsn/a

Switchesn/a

Material of ConstructionMetal

Form Factors SupportedVertical rackmount installation supported with included mounting brackets supports toolless mounting in button-mount compatible racks

PDU Form FactorVertical (0U)

Storage Temperature Range5 to 122F (-15 to 50C)