MPN: PDU3VN6G60B
Category: UPS >> Surge Protection
Vendor: Tripp-Lite
Weight: 33 LB(S)
Price: US$ 1083.75
PDU Type
Monitored
Output Capacity
Details 14.5kW (240V), 13.9kW (230V), 13.3kW (220V), 12.6kW (208V), 12.1kW (200V) total capacity 20A max per breakered outlet bank 16A max per C19 outlet 12A max per C13 outlet
Frequency Compatibility
50 / 60 Hz
Output Receptacles
(42) C13, (6) C19
Output Nominal Voltage
200, 208, 240
Overload Protection
3 20A circuit breakers, 1 per outlet bank
PDU Input Voltage
200, 208, 240
Recommended Electrical Service
60A 208/240V with IEC309 60A Blue (3P+E) outlet
Maximum Input Amps
35
PDU Plug Type
IEC-309 60A BLUE (3P+E)
Input Cord Length (m)
1.8
Input Phase
3-Phase
Reported Load Segments
Reports input current per phase (L1, L2, L3) and output current for each breakered load bank (20A balanced max per banks B1-B3), Outlets are color-coded and labelled for phase and load bank identification, L1-L2 feeds black outlets (B1), L2-L3 feeds dark-gray outlets (B2) L3-L1 feeds light-gray outlets (B3)
Front Panel LCD Display
Large digital display reports Amperage, Kilowatts, Voltage, Unbalance percentage, Temperature and Humidity information (requires ENIVIROSENSE option) Small digital display provides detail on the measurement the large display is reporting: Input-phase (L), Load bank (B), Sensor (S), Load unbalance (UB), Output power (OP)
Front Panel LEDs
Set of 6 LEDs identify the value displayed on the large digital display: Amperage (A), Kilowatts (kW), Voltage (V), Unbalance percentage ( percent UB), Temperature (T), Humidity (percent RH), One additional LED for each output load bank (B1-B3) offers information power availablity: GREEN (<80 percent load), YELLOW (>80 percent load), RED (Power OFF), RED FLASHING (Power OFF/breaker trip)
Switches
Set of UP/DOWN arrow buttons scroll through available Input, Bank, Power, Load balance and Sensor options, Additional MODE button advances the LEDs to view the next measurement
Material of Construction
Metal
Form Factors Supported
Vertical rackmount installation supported with included mounting brackets supports tooless mounting in button-mount compatible racks
PDU Form Factor
Vertical (0U)
Operating Temperature Range
32 to 122F (0C to 50C)