| Item | 
			S5700(S)-LI/S5710-LI* | 
			S5700-SI* | 
			S5700-EI/S5710-EI/S5720-EI* | 
			S5700-HI/S5710-HI/S5720-HI* | 
		
		
			| Fixed port | 
			LI | 
			S5700-10P-LI-AC/S5700-10P-PWR-LI-AC: 8 × 10/100/1000Base-T,2 × 1000Base-X SFP | 
		
		
			| S5700(S)-28P-LI/S5700-28P-PWR-LI/ S5700-28P-LI-BAT/S5700-28P-LI-4AH: 24 × 10/100/1000Base-T, 4 × 1000Base-X SFP | 
		
		
			| S5700-28P-LI-24S-BAT/S5700-28P-LI-24S-4AH: 28 × 1000Base-X,4 of which are dual-purpose 10/100/1000 or SFP, 4 × 1000Base-X | 
		
		
			| S5700-28TP-LI-AC/S5700-28TP-PWR-LI-AC/S5701-28TP-PWR-LI- AC:24× 10/100/1000Base-T, 2×1000Base-X SFP and 2 dual-purpose 10/100/1000 or SFP | 
		
		
			| S5700-28X-LI/S5700-28X-PWR-LI-AC/ S5701-28X-LI-AC: 24 × 10/100/1000Base-T, 4 × 10GE SFP+ | 
		
		
			| S5700-28X-LI-24S-AC/S5700-28X-LI-24S-DC/ S5701-28X-LI-24S-AC: 28x1000Base-X,4 of which are dual-purpose 10/100/1000 or SFP,4 × 10GE SFP+ | 
		
		
			| S5700(S)-52P-LI/S5700-52P-PWR-LI: 48 × 10/100/1000Base-T, 4 × 1000Base-X SFP | 
		
		
			| S5700-52X-LI/S5700-52X-PWR-LI-AC: 48 × 10/100/1000Base-T, 4 × 10GE SFP+ | 
		
		
			| S5700-52X-LI-48CS-AC:48x1000Base-X(CSFP) or 24 × 1000Base-X, 4 of which are dual-purpose 10/100/1000 or Base-X(CSFP), 4 × 10GE SFP+ | 
		
		
			| SI | 
			S5700-24TP-SI/S5700-24TP-PWR-SI/S5700-28C-SI/S5700-28C-PWR-SI:24 × 10/100/1000Base-T, 4 of which are dual-purpose 10/100/1000 or SFP | 
		
		
			| S5700-26X-SI-12S-AC: 12 × 10/100/1000BASE-T,12×100/1000Base-X,2 × 10GE SFP+ | 
		
		
			| S5700-48TP-SI/S5700-48TP-PWR-SI: 48 × 10/100/1000Base-T, 4 of which are dual-purpose 10/100/1000 or SFP | 
		
		
			| S5700-52C-SI/S5700-52C-PWR-SI: 48 × 10/100/1000Base-T | 
		
		
			| EI | 
			S5700-28C-EI/S5700-28C-PWR-EI: 24 × 10/100/1000Base-T | 
		
		
			| S5700-52C-EI/S5700-52C-PWR-EI: 48 × 10/100/1000Base-T | 
		
		
			| S5700-28C-EI-24S: 20 × 100/1000Base-X, 4 × GE Combo | 
		
		
			| S5710-28C-EI/S5710-28C-PWR-EI-AC: 20 x 10/100/1000Base-T, 4 × GE Combo, 4 × 10GE SFP+ | 
		
		
			| S5710-52C-EI/S5710-52C-PWR-EI/S5710-52C-PWR-EI-AC: 48 x 10/100/1000Base-T, 4 × 10GE SFP+ | 
		
		
			| S5720-32P-EI-AC: 24×10/100/1000Base-T(4GE Combo SFP), 4×100/1000Base-X SFP, 4 Gig SFP | 
		
		
			| S5720-52P-EI-AC:48×10/100/1000Base-T, 4 Gig SFP | 
		
		
			| S5720-36C-EI-AC/S5720-36C-PWR-EI-AC: 28×10/100/1000Base-T(4GE Combo SFP), 4×10 GE SFP+ | 
		
		
			| S5720-36C-EI-28S-AC:28×100/1000Base-X SFP(4GE Combo), 4×10GE SFP+ | 
		
		
			| S5720-36PC-EI-AC: 28×10/100/1000Base-T(4GE Combo SFP), 4 Gig SFP | 
		
		
			| S5720-56C-EI-AC/ S5720-56C-PWR-EI-AC:48×10/100/1000Base-T, 4×10GE SFP+ | 
		
		
			| S5720-56C-EI-48S-AC: 48×100/1000Base-X SFP, 4×10GE SFP+ | 
		
		
			| S5720-56PC-EI-AC: 48×10/100/1000Base-T, 4 Gig SFP | 
		
		
			| S5720-32X-EI-AC: 24×10/100/1000 Base-T, 4×100/1000Base-X SFP, 4×10 GE SFP+, 2 QSFP+ | 
		
		
			| S5720-32X-EI-24S-AC: 24×100/1000Base-X SFP, 4×10/100/1000Base-T, 4×10GE SFP+, 2 QSFP+ | 
		
		
			| S5720-50X-EI-AC : 46 ×10/100/1000Base-T, 4×10GE SFP+, 2 QSFP+ | 
		
		
			| S5720-50X-EI-46S-AC: 46 ×10/100/1000Base-X SFP, 4×10GE SFP+, 2 QSFP+ | 
		
		
			| S5720-52X-EI-AC: 48×10/100/1000Base-T, 4×10GE SFP+ | 
		
		
			| HI | 
			S5700-28C-HI: 24 × 10/100/1000Base-T | 
		
		
			| S5700-28C-HI-24S: 24 × 100/1000Base-X | 
		
		
			| S5710-108C-PWR-HI: 48 × 10/100/1000BASE-T, 8 × 10GE SFP+ | 
		
		
			| S5720-32C-HI-24S-AC:24×100/1000Base-X ,8 of which are dual-purpose 10/100/1000 or SFP, 4×10GE SFP+ | 
		
		
			| S5720-56C-HI-AC/S5720-56C-PWR-HI-AC:48×10/100/1000Base-T, 4×10GE SFP+ | 
		
		
			| MAC address table | 
			IEEE 802.1d compliance | 
		
		
			| MAC address learning and aging | 
		
		
			| Static, dynamic, and blackhole MAC address entries | 
		
		
			| Packet filtering based on source MAC addresses | 
		
		
			MAC address entries: 
			S5700S-LI series: 8K, S5700-LI/S5700-SI series: 16K, S5700-EI series: 32K, S5720-EI series: 64K, S5700-HI series: S5700-HI: 32K, S5710-HI: 456K, S5720-HI: 128K | 
		
		
			| VLAN | 
			4K VLANs | 
		
		
			| Guest VLAN and voice VLAN | 
		
		
			| GVRP | 
		
		
			| MUX VLAN | 
		
		
			| VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports | 
		
		
			| 1:1 and N:1 VLAN Mapping | 
		
		
			| SuperVLAN(supported by the S5700-SI/S5700-EI/S5700-HI series) | 
		
		
			| Ring protection | 
			RRPP ring topology and RRPP multi-instance | 
		
		
			| Smart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchover | 
		
		
			| SEP | 
		
		
			| ERPS(G.8032)(supported by the S5700-LI/S5700-SI/S5700-EI/S5700-HI series) | 
		
		
			| STP, RSTP, and MSTP | 
		
		
			| BPDU protection, root protection, and loop protection | 
		
		
			| BPDU Tunnel | 
		
		
			| Reliability | 
			Ethernet OAM (IEEE 802.3ah and 802.1ag) | 
		
		
			| ITU-Y.1731 | 
		
		
			| DLDP | 
		
		
			| LACP | 
		
		
			| E-Trunk(supported by the S5700-SI/S5700-EI/S5700-HI series) | 
		
		
			| BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM (supported by the S5700-EI/S5700-HI series) | 
		
		
			| MPLS features | 
			MPLS L3VPN | 
		
		
			| MPLS L2VPN(VPWS/VPLS) | 
		
		
			| MPLS-TE | 
		
		
			| MPLS QoS | 
		
		
			| Notes: supported by S5710-EI, S5700-HI and S5710-HI | 
		
		
			| IP routing | 
			Static routing | 
		
		
			| RIPv1, RIPv2 and RIPng,ECMP(supported by the S5700-SI/S5700-EI/S5700-HI series) | 
		
		
			| OSPF, OSPFv3, IS-IS, IS-ISv6, BGP and BGP4+ (supported by the S5700-EI/S5700-HI series) | 
		
		
			| IPv6 features | 
			Neighbor Discovery (ND) | 
		
		
			| Path MTU (PMTU) | 
		
		
			| IPv6 ping, IPv6 tracert, and IPv6 Telnet | 
		
		
			| ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type | 
		
		
			| MLD v1/v2 snooping | 
		
		
			| 6to4 tunnel, ISATAP tunnel, and manually configured tunnel(supported by the S5700-SI/S5700-EI/S5700-HI series) | 
		
		
			| Multicast | 
			IGMP v1/v2/v3 snooping and IGMP fast leave | 
		
		
			| Multicast forwarding in a VLAN and multicast replication between VLANs | 
		
		
			| Multicast load balancing among member ports of a trunk | 
		
		
			| Controllable multicast | 
		
		
			| Port-based multicast traffic statistics | 
		
		
			| IGMP v1/v2/v3, PIM-SM, PIM-DM, PIM-SSM, MSDP (supported by the S5700-EI/S5700-HI series) | 
		
		
			| QoS/ACL | 
			Rate limiting on packets sent and received by an interface | 
		
		
			| Packet redirection | 
		
		
			| Port-based traffic policing and two-rate three-color CAR | 
		
		
			| Eight queues on each port | 
		
		
			| WRR, DRR, SP, WRR+SP, and DRR+SP queue scheduling algorithms | 
		
		
			| WRED (supported by the S5710-EI and S5700-HI) | 
		
		
			| Re-marking of the 802.1p priority and DSCP priority | 
		
		
			| Packet filtering at Layers 2 through 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID | 
		
		
			| Rate limiting in each queue and traffic shaping on ports | 
		
		
			| Security | 
			User privilege management and password protection | 
		
		
			| DoS attack defense, ARP attack defense, and ICMP attack defense | 
		
		
			| Binding of the IP address, MAC address, interface, and VLAN | 
		
		
			| Port isolation, port security, and sticky MAC | 
		
		
			| MFF | 
		
		
			| Blackhole MAC address entries | 
		
		
			| Limit on the number of learned MAC addresses | 
		
		
			| 802.1x authentication and limit on the number of users on an interface | 
		
		
			| AAA authentication, RADIUS authentication, HWTACACS authentication, and NAC | 
		
		
			| SSH v2.0 | 
		
		
			| Hypertext Transfer Protocol Secure (HTTPS) | 
		
		
			| CPU defense | 
		
		
			| Blacklist and whitelist | 
		
		
			| Access Security | 
			DHCP Relay, DHCP Server, DHCP Snooping, DHCP Security | 
		
		
			| Management and maintenance | 
			Virtual cable test | 
		
		
			| Port mirroring and RSPAN (remote port mirroring) | 
		
		
			| Remote configuration and maintenance using Telnet | 
		
		
			| SNMP v1/v2/v3 | 
		
		
			| RMON | 
		
		
			| Web NMS | 
		
		
			| HGMP | 
		
		
			| System logs and alarms of different levels | 
		
		
			| 802.3az EEE (supported by the S5700(S)-LI, S5710-EI, S5700-HI and S5710-HI) | 
		
		
			| Dying gasp (supported by the S5700-HI, S5710-HI and S5700(S)-LI(except battery LAN switches) | 
		
		
			| NetStream (supported by the S5710-EI, S5700-HI and S5710-HI) | 
		
		
			| sFlow(supported by the S5700(S)-LI/S5700-EI/S5700-HI series) | 
		
		
			| Interoperability | 
			Supports VBST (Compatible with PVST/PVST+/RPVST) | 
		
		
			| Supports LNP (Similar to DTP) | 
		
		
			| Supports VCMP (Similar to VTP) | 
		
		
			| Operating environment | 
			Operating temperature: 0℃–50℃ | 
		
		
			| Relative humidity: 10%–90% (non-condensing) | 
		
		
			| Input voltage | 
			AC: | 
		
		
			| Rated voltage range: 100 V to 240 V AC, 50/60 Hz | 
		
		
			| Maximum voltage range: 90 V to 264 V AC, 47/63 Hz | 
		
		
			| DC: | 
		
		
			| Rated voltage range: –48 V to –60 V, DC | 
		
		
			| Maximum voltage range: –36 V to –72 V DC | 
		
		
			| Note: PoE-support switches do not use DC power supplies. | 
		
		
			| Dimensions (W x D x H) | 
			S5700-10P-LI-AC:250 x 180 x 43.6 mm | 
		
		
			| S5700-10P-PWR-LI-AC:320 x 220 x 43.6 mm | 
		
		
			| S5700-28P-LI/S5700-28TP-LI-AC/S5700-28X-LI/S5700-28X-LI-24S/S5700-24TP-SI/S5700-28C-HI/S5700-28C-HI-24S/ S5701-28X-LI-AC/ S5701-28X-LI-24S-AC/ S5700-52X-LI-48CS-AC: 442 x 220 x 43.6 mm | 
		
		
			| S5700-28P-PWR-LI/S5700-28TP-PWR-LI-AC/S5701-28TP-PWR-LI-AC/S5700-52P-LI/S5700-52P-PWR-LI/S5700-28X-PWR-LI-AC/S5700-52X-LI/S5700-52X-PWR-LI-AC/ S5700-26X-SI-12S-AC/S5700-28P-LI-BAT/S5700-28P-LI-4AH/S5700-28P-LI-24S-BAT/S5700-28P-LI-24S-4AH: 442 x 310 x 43.6 mm | 
		
		
			| S5710-108C-PWR-HI: 442x470.0x87.2 | 
		
		
			| Others: 442 x 420 x 43.6 mm | 
		
		
			| Powerconsumption | 
			S5700-10P-LI-AC<11.5W | 
		
		
			| S5700-10P-PWR-LI-AC<139W | 
		
		
			| S5700-28P-LI<25W | 
			S5700-24TP-SI<40W | 
			S5700-28C-EI<60W | 
			S5700-28C-HI<76W | 
		
		
			| S5700S-28P-LI<25W | 
			S5700-26X-SI-12S-AC<42.3W | 
			S5700-28C-EI-24S<63W | 
			S5700-28C-HI-24S<80W | 
		
		
			| S5700-28TP-LI-AC<26.4W | 
			S5700-48TP-SI<64W | 
			S5700-52C-EI<88W | 
			S5710-108C-PWR-HI<1680W (PoE:1440W) | 
		
		
			| S5700-28TP-PWR-LI-AC<469.7W(PoE:370W) | 
			S5700-28C-SI<56W | 
			S5710-28C-EI<100W | 
		
		
			| S5701-28TP-PWR-LI-AC<238.7W(PoE:185W) | 
			S5700-52C-SI<78W | 
			S5710-52C-EI<165W | 
			S5720-32C-HI-24S-AC<172.7W | 
		
		
			| S5700-52P-LI<52W | 
			S5700-24TP-PWR-SI<455W(PoE: 370W) | 
			S5700-28C-PWR-EI<842W (PoE: 740W) | 
			S5720-56C-HI-AC<183.3W | 
		
		
			| S5700S-52P-LI<52W | 
			S5700-48TP-PWR-SI<907W (PoE: 740W) | 
			
			 S5720-56C-PWR-HI-AC: 
			without PD: <188.74W, 
			with PD: <1739W(device: 
			299W, PD: 1440W) 
			 | 
		
		
			| S5700-52C-PWR-EI<930W (PoE: 740W) | 
			  | 
		
		
			| S5700-28P-PWR-LI<765W (PoE: 740W) | 
			  | 
			  | 
		
		
			| S5710-28C-PWR-EI-AC<942W | 
			  | 
		
		
			|   | 
			S5710-52C-PWR-EI/S5710-52C-PWR-EI-AC: < 1043W with two 580W AC supplies(PoE:740W), or <1625W with two 1150W AC supplies(PoE:1440W) | 
			  | 
		
		
			| S5710-28C-PWR-LI<836W (PoE: 740W) | 
			  | 
			  | 
		
		
			|   | 
			  | 
		
		
			| S5700-52P-PWR-LI<792W (PoE: 740W) | 
			  | 
			  | 
			  | 
		
		
			|   | 
			  | 
			  | 
		
		
			| S5710-52C-PWR-LI<917W (PoE: 740W) | 
			  | 
			  | 
			  | 
		
		
			|   | 
			  | 
			  | 
		
		
			| S5700-28X-LI<42W | 
			  | 
			  | 
			  | 
		
		
			| S5700-28X-LI-24S<54W | 
			  | 
			  | 
			  | 
		
		
			| S5700-28X-PWR-LI-AC <420W | 
			  | 
			  | 
			  | 
		
		
			| S5700-52X-LI<61W | 
			  | 
			  | 
			  | 
		
		
			| S5700-52X-PWR-LI-AC <440 | 
			  | 
			  | 
			  | 
		
		
			| S5700-28P-LI-BAT/S5700-28P-LI-4AH<23W | 
			  | 
			  | 
			  | 
		
		
			| S5700-28P-LI-24S-BAT/S5700-28P-LI-24S-4AH<34.1W | 
			  | 
			  | 
			  | 
		
		
			| S5700-52X-LI-48CS-AC<79.9W | 
			  | 
			  | 
			  | 
		
		
			| S5701-28X-LI-AC <39.5W | 
			  | 
			  | 
			  | 
		
		
			| S5701-28X-LI-24S-AC<60W | 
			  | 
			  | 
			  |