| Item |
S5700(S)-LI/S5710-LI* |
S5700-SI* |
S5700-EI/S5710-EI/S5720-EI* |
S5700-HI/S5710-HI/S5720-HI* |
| Fixed port |
LI |
S5700-10P-LI-AC/S5700-10P-PWR-LI-AC: 8 × 10/100/1000Base-T,2 × 1000Base-X SFP |
| S5700(S)-28P-LI/S5700-28P-PWR-LI/ S5700-28P-LI-BAT/S5700-28P-LI-4AH: 24 × 10/100/1000Base-T, 4 × 1000Base-X SFP |
| S5700-28P-LI-24S-BAT/S5700-28P-LI-24S-4AH: 28 × 1000Base-X,4 of which are dual-purpose 10/100/1000 or SFP, 4 × 1000Base-X |
| S5700-28TP-LI-AC/S5700-28TP-PWR-LI-AC/S5701-28TP-PWR-LI- AC:24× 10/100/1000Base-T, 2×1000Base-X SFP and 2 dual-purpose 10/100/1000 or SFP |
| S5700-28X-LI/S5700-28X-PWR-LI-AC/ S5701-28X-LI-AC: 24 × 10/100/1000Base-T, 4 × 10GE SFP+ |
| S5700-28X-LI-24S-AC/S5700-28X-LI-24S-DC/ S5701-28X-LI-24S-AC: 28x1000Base-X,4 of which are dual-purpose 10/100/1000 or SFP,4 × 10GE SFP+ |
| S5700(S)-52P-LI/S5700-52P-PWR-LI: 48 × 10/100/1000Base-T, 4 × 1000Base-X SFP |
| S5700-52X-LI/S5700-52X-PWR-LI-AC: 48 × 10/100/1000Base-T, 4 × 10GE SFP+ |
| S5700-52X-LI-48CS-AC:48x1000Base-X(CSFP) or 24 × 1000Base-X, 4 of which are dual-purpose 10/100/1000 or Base-X(CSFP), 4 × 10GE SFP+ |
| SI |
S5700-24TP-SI/S5700-24TP-PWR-SI/S5700-28C-SI/S5700-28C-PWR-SI:24 × 10/100/1000Base-T, 4 of which are dual-purpose 10/100/1000 or SFP |
| S5700-26X-SI-12S-AC: 12 × 10/100/1000BASE-T,12×100/1000Base-X,2 × 10GE SFP+ |
| S5700-48TP-SI/S5700-48TP-PWR-SI: 48 × 10/100/1000Base-T, 4 of which are dual-purpose 10/100/1000 or SFP |
| S5700-52C-SI/S5700-52C-PWR-SI: 48 × 10/100/1000Base-T |
| EI |
S5700-28C-EI/S5700-28C-PWR-EI: 24 × 10/100/1000Base-T |
| S5700-52C-EI/S5700-52C-PWR-EI: 48 × 10/100/1000Base-T |
| S5700-28C-EI-24S: 20 × 100/1000Base-X, 4 × GE Combo |
| S5710-28C-EI/S5710-28C-PWR-EI-AC: 20 x 10/100/1000Base-T, 4 × GE Combo, 4 × 10GE SFP+ |
| S5710-52C-EI/S5710-52C-PWR-EI/S5710-52C-PWR-EI-AC: 48 x 10/100/1000Base-T, 4 × 10GE SFP+ |
| S5720-32P-EI-AC: 24×10/100/1000Base-T(4GE Combo SFP), 4×100/1000Base-X SFP, 4 Gig SFP |
| S5720-52P-EI-AC:48×10/100/1000Base-T, 4 Gig SFP |
| S5720-36C-EI-AC/S5720-36C-PWR-EI-AC: 28×10/100/1000Base-T(4GE Combo SFP), 4×10 GE SFP+ |
| S5720-36C-EI-28S-AC:28×100/1000Base-X SFP(4GE Combo), 4×10GE SFP+ |
| S5720-36PC-EI-AC: 28×10/100/1000Base-T(4GE Combo SFP), 4 Gig SFP |
| S5720-56C-EI-AC/ S5720-56C-PWR-EI-AC:48×10/100/1000Base-T, 4×10GE SFP+ |
| S5720-56C-EI-48S-AC: 48×100/1000Base-X SFP, 4×10GE SFP+ |
| S5720-56PC-EI-AC: 48×10/100/1000Base-T, 4 Gig SFP |
| S5720-32X-EI-AC: 24×10/100/1000 Base-T, 4×100/1000Base-X SFP, 4×10 GE SFP+, 2 QSFP+ |
| S5720-32X-EI-24S-AC: 24×100/1000Base-X SFP, 4×10/100/1000Base-T, 4×10GE SFP+, 2 QSFP+ |
| S5720-50X-EI-AC : 46 ×10/100/1000Base-T, 4×10GE SFP+, 2 QSFP+ |
| S5720-50X-EI-46S-AC: 46 ×10/100/1000Base-X SFP, 4×10GE SFP+, 2 QSFP+ |
| S5720-52X-EI-AC: 48×10/100/1000Base-T, 4×10GE SFP+ |
| HI |
S5700-28C-HI: 24 × 10/100/1000Base-T |
| S5700-28C-HI-24S: 24 × 100/1000Base-X |
| S5710-108C-PWR-HI: 48 × 10/100/1000BASE-T, 8 × 10GE SFP+ |
| S5720-32C-HI-24S-AC:24×100/1000Base-X ,8 of which are dual-purpose 10/100/1000 or SFP, 4×10GE SFP+ |
| S5720-56C-HI-AC/S5720-56C-PWR-HI-AC:48×10/100/1000Base-T, 4×10GE SFP+ |
| MAC address table |
IEEE 802.1d compliance |
| MAC address learning and aging |
| Static, dynamic, and blackhole MAC address entries |
| Packet filtering based on source MAC addresses |
MAC address entries:
S5700S-LI series: 8K, S5700-LI/S5700-SI series: 16K, S5700-EI series: 32K, S5720-EI series: 64K, S5700-HI series: S5700-HI: 32K, S5710-HI: 456K, S5720-HI: 128K |
| VLAN |
4K VLANs |
| Guest VLAN and voice VLAN |
| GVRP |
| MUX VLAN |
| VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports |
| 1:1 and N:1 VLAN Mapping |
| SuperVLAN(supported by the S5700-SI/S5700-EI/S5700-HI series) |
| Ring protection |
RRPP ring topology and RRPP multi-instance |
| Smart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchover |
| SEP |
| ERPS(G.8032)(supported by the S5700-LI/S5700-SI/S5700-EI/S5700-HI series) |
| STP, RSTP, and MSTP |
| BPDU protection, root protection, and loop protection |
| BPDU Tunnel |
| Reliability |
Ethernet OAM (IEEE 802.3ah and 802.1ag) |
| ITU-Y.1731 |
| DLDP |
| LACP |
| E-Trunk(supported by the S5700-SI/S5700-EI/S5700-HI series) |
| BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM (supported by the S5700-EI/S5700-HI series) |
| MPLS features |
MPLS L3VPN |
| MPLS L2VPN(VPWS/VPLS) |
| MPLS-TE |
| MPLS QoS |
| Notes: supported by S5710-EI, S5700-HI and S5710-HI |
| IP routing |
Static routing |
| RIPv1, RIPv2 and RIPng,ECMP(supported by the S5700-SI/S5700-EI/S5700-HI series) |
| OSPF, OSPFv3, IS-IS, IS-ISv6, BGP and BGP4+ (supported by the S5700-EI/S5700-HI series) |
| IPv6 features |
Neighbor Discovery (ND) |
| Path MTU (PMTU) |
| IPv6 ping, IPv6 tracert, and IPv6 Telnet |
| ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type |
| MLD v1/v2 snooping |
| 6to4 tunnel, ISATAP tunnel, and manually configured tunnel(supported by the S5700-SI/S5700-EI/S5700-HI series) |
| Multicast |
IGMP v1/v2/v3 snooping and IGMP fast leave |
| Multicast forwarding in a VLAN and multicast replication between VLANs |
| Multicast load balancing among member ports of a trunk |
| Controllable multicast |
| Port-based multicast traffic statistics |
| IGMP v1/v2/v3, PIM-SM, PIM-DM, PIM-SSM, MSDP (supported by the S5700-EI/S5700-HI series) |
| QoS/ACL |
Rate limiting on packets sent and received by an interface |
| Packet redirection |
| Port-based traffic policing and two-rate three-color CAR |
| Eight queues on each port |
| WRR, DRR, SP, WRR+SP, and DRR+SP queue scheduling algorithms |
| WRED (supported by the S5710-EI and S5700-HI) |
| Re-marking of the 802.1p priority and DSCP priority |
| Packet filtering at Layers 2 through 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID |
| Rate limiting in each queue and traffic shaping on ports |
| Security |
User privilege management and password protection |
| DoS attack defense, ARP attack defense, and ICMP attack defense |
| Binding of the IP address, MAC address, interface, and VLAN |
| Port isolation, port security, and sticky MAC |
| MFF |
| Blackhole MAC address entries |
| Limit on the number of learned MAC addresses |
| 802.1x authentication and limit on the number of users on an interface |
| AAA authentication, RADIUS authentication, HWTACACS authentication, and NAC |
| SSH v2.0 |
| Hypertext Transfer Protocol Secure (HTTPS) |
| CPU defense |
| Blacklist and whitelist |
| Access Security |
DHCP Relay, DHCP Server, DHCP Snooping, DHCP Security |
| Management and maintenance |
Virtual cable test |
| Port mirroring and RSPAN (remote port mirroring) |
| Remote configuration and maintenance using Telnet |
| SNMP v1/v2/v3 |
| RMON |
| Web NMS |
| HGMP |
| System logs and alarms of different levels |
| 802.3az EEE (supported by the S5700(S)-LI, S5710-EI, S5700-HI and S5710-HI) |
| Dying gasp (supported by the S5700-HI, S5710-HI and S5700(S)-LI(except battery LAN switches) |
| NetStream (supported by the S5710-EI, S5700-HI and S5710-HI) |
| sFlow(supported by the S5700(S)-LI/S5700-EI/S5700-HI series) |
| Interoperability |
Supports VBST (Compatible with PVST/PVST+/RPVST) |
| Supports LNP (Similar to DTP) |
| Supports VCMP (Similar to VTP) |
| Operating environment |
Operating temperature: 0℃–50℃ |
| Relative humidity: 10%–90% (non-condensing) |
| Input voltage |
AC: |
| Rated voltage range: 100 V to 240 V AC, 50/60 Hz |
| Maximum voltage range: 90 V to 264 V AC, 47/63 Hz |
| DC: |
| Rated voltage range: –48 V to –60 V, DC |
| Maximum voltage range: –36 V to –72 V DC |
| Note: PoE-support switches do not use DC power supplies. |
| Dimensions (W x D x H) |
S5700-10P-LI-AC:250 x 180 x 43.6 mm |
| S5700-10P-PWR-LI-AC:320 x 220 x 43.6 mm |
| S5700-28P-LI/S5700-28TP-LI-AC/S5700-28X-LI/S5700-28X-LI-24S/S5700-24TP-SI/S5700-28C-HI/S5700-28C-HI-24S/ S5701-28X-LI-AC/ S5701-28X-LI-24S-AC/ S5700-52X-LI-48CS-AC: 442 x 220 x 43.6 mm |
| S5700-28P-PWR-LI/S5700-28TP-PWR-LI-AC/S5701-28TP-PWR-LI-AC/S5700-52P-LI/S5700-52P-PWR-LI/S5700-28X-PWR-LI-AC/S5700-52X-LI/S5700-52X-PWR-LI-AC/ S5700-26X-SI-12S-AC/S5700-28P-LI-BAT/S5700-28P-LI-4AH/S5700-28P-LI-24S-BAT/S5700-28P-LI-24S-4AH: 442 x 310 x 43.6 mm |
| S5710-108C-PWR-HI: 442x470.0x87.2 |
| Others: 442 x 420 x 43.6 mm |
| Powerconsumption |
S5700-10P-LI-AC<11.5W |
| S5700-10P-PWR-LI-AC<139W |
| S5700-28P-LI<25W |
S5700-24TP-SI<40W |
S5700-28C-EI<60W |
S5700-28C-HI<76W |
| S5700S-28P-LI<25W |
S5700-26X-SI-12S-AC<42.3W |
S5700-28C-EI-24S<63W |
S5700-28C-HI-24S<80W |
| S5700-28TP-LI-AC<26.4W |
S5700-48TP-SI<64W |
S5700-52C-EI<88W |
S5710-108C-PWR-HI<1680W (PoE:1440W) |
| S5700-28TP-PWR-LI-AC<469.7W(PoE:370W) |
S5700-28C-SI<56W |
S5710-28C-EI<100W |
| S5701-28TP-PWR-LI-AC<238.7W(PoE:185W) |
S5700-52C-SI<78W |
S5710-52C-EI<165W |
S5720-32C-HI-24S-AC<172.7W |
| S5700-52P-LI<52W |
S5700-24TP-PWR-SI<455W(PoE: 370W) |
S5700-28C-PWR-EI<842W (PoE: 740W) |
S5720-56C-HI-AC<183.3W |
| S5700S-52P-LI<52W |
S5700-48TP-PWR-SI<907W (PoE: 740W) |
S5720-56C-PWR-HI-AC:
without PD: <188.74W,
with PD: <1739W(device:
299W, PD: 1440W)
|
| S5700-52C-PWR-EI<930W (PoE: 740W) |
|
| S5700-28P-PWR-LI<765W (PoE: 740W) |
|
|
| S5710-28C-PWR-EI-AC<942W |
|
| |
S5710-52C-PWR-EI/S5710-52C-PWR-EI-AC: < 1043W with two 580W AC supplies(PoE:740W), or <1625W with two 1150W AC supplies(PoE:1440W) |
|
| S5710-28C-PWR-LI<836W (PoE: 740W) |
|
|
| |
|
| S5700-52P-PWR-LI<792W (PoE: 740W) |
|
|
|
| |
|
|
| S5710-52C-PWR-LI<917W (PoE: 740W) |
|
|
|
| |
|
|
| S5700-28X-LI<42W |
|
|
|
| S5700-28X-LI-24S<54W |
|
|
|
| S5700-28X-PWR-LI-AC <420W |
|
|
|
| S5700-52X-LI<61W |
|
|
|
| S5700-52X-PWR-LI-AC <440 |
|
|
|
| S5700-28P-LI-BAT/S5700-28P-LI-4AH<23W |
|
|
|
| S5700-28P-LI-24S-BAT/S5700-28P-LI-24S-4AH<34.1W |
|
|
|
| S5700-52X-LI-48CS-AC<79.9W |
|
|
|
| S5701-28X-LI-AC <39.5W |
|
|
|
| S5701-28X-LI-24S-AC<60W |
|
|
|