The QCP board is a highly integrated protection unit and it supports a maximum of four intra-board 1+1
protection groups or client 1+1 protection groups.
Initial Version:
8800 V100R008C10SPC200
9800 V100R001C20
Application
Mechanic Specifications
Weight
(kg/lb.)
Typical power
consumption
Maximum power
consumption
1.2 (2.65)
6.2 W
6.8 W
Function
Function
Description
Basic function
n
Provides protection for four services.
•Intra-board 1+1 protection: protects
services for OTU boards that have no
dual-feeding and selective receiving
function.
•Client 1+1 protection: protects services
using the working and protection OTU
boards.
Spectrum
application
Supports extended C-band wavelengths
Optical-layer ASON
Supported
Protection
Dual-fed and selective receiving.
Optical Specifications
Item
Unit
Value
Insertion loss at the transmit end
dB
≤4
Insertion loss at the receive end
dB
≤1.5
Range of the input optical power
dBm
-35 to 20
Operating wavelength range
nm
1270 to 1350,
1528 to 1567
Switching threshold of optical
power difference
dB
5
Range of the alarm threshold for
the optical power difference
dB
3 to 8
Slot
Single-slot board (8800 slot)
OptiX OSN 8800 T64 subrack
IU1-IU8, IU11-IU42, IU45-IU68
OptiX OSN 8800 T32 subrack
IU1-IU8, IU12-IU27, IU29-IU36
OptiX OSN 8800 T16 subrack
IU1-IU18
OptiX OSN 8800 universal platform subrack
IU1-IU16
6800
IU1-IU17
3800
IU11, IU2-IU5
Single-slot board (9800 slot)
OptiX OSN 9800 universal platform subrack: IU1-IU16