Overview
The Huawei S5700 Series is a flexible platform that lets you optimize L3 switching capacity and downstream port bandwidth from 100 Mbit/s to 1 Gbit/s in a highly reliable and energy-efficient switch.
- 10 GE uplink ports with intelligent iStack technology allow up to 9 switches to be combined into a single stack for easy scalability.
- Advanced VLAN design combined with Huawei's eSight management system provide simple, secure, automated methods for configuring the network, including remote upgrades, saving time and reducing network communication faults.
- Energy-saving features and PoE support match power needs with powered devices (IP phones, WLAN access points); idle and hibernation modes reduce energy consumption without compromising stability.
Product Specifications
| Item | S5700(S)-LI/S5710-LI* | S5700-SI* | S5700-EI/S5710-EI/S5720-EI* | S5700-HI/S5710-HI/S5720-HI* | |
|---|---|---|---|---|---|
| Fixed port | LI | S5700-10P-LI-AC/S5700-10P-PWR-LI-AC: 8 × 10/100/1000Base-T,2 × 1000Base-X SFP | |||
| S5700(S)-28P-LI/S5700-28P-PWR-LI/ S5700-28P-LI-BAT/S5700-28P-LI-4AH: 24 × 10/100/1000Base-T, 4 × 1000Base-X SFP | |||||
| S5700-28P-LI-24S-BAT/S5700-28P-LI-24S-4AH: 28 × 1000Base-X,4 of which are dual-purpose 10/100/1000 or SFP, 4 × 1000Base-X | |||||
| S5700-28TP-LI-AC/S5700-28TP-PWR-LI-AC/S5701-28TP-PWR-LI- AC:24× 10/100/1000Base-T, 2×1000Base-X SFP and 2 dual-purpose 10/100/1000 or SFP | |||||
| S5700-28X-LI/S5700-28X-PWR-LI-AC/ S5701-28X-LI-AC: 24 × 10/100/1000Base-T, 4 × 10GE SFP+ | |||||
| S5700-28X-LI-24S-AC/S5700-28X-LI-24S-DC/ S5701-28X-LI-24S-AC: 28x1000Base-X,4 of which are dual-purpose 10/100/1000 or SFP,4 × 10GE SFP+ | |||||
| S5700(S)-52P-LI/S5700-52P-PWR-LI: 48 × 10/100/1000Base-T, 4 × 1000Base-X SFP | |||||
| S5700-52X-LI/S5700-52X-PWR-LI-AC: 48 × 10/100/1000Base-T, 4 × 10GE SFP+ | |||||
| S5700-52X-LI-48CS-AC:48x1000Base-X(CSFP) or 24 × 1000Base-X, 4 of which are dual-purpose 10/100/1000 or Base-X(CSFP), 4 × 10GE SFP+ | |||||
| SI | S5700-24TP-SI/S5700-24TP-PWR-SI/S5700-28C-SI/S5700-28C-PWR-SI:24 × 10/100/1000Base-T, 4 of which are dual-purpose 10/100/1000 or SFP | ||||
| S5700-26X-SI-12S-AC: 12 × 10/100/1000BASE-T,12×100/1000Base-X,2 × 10GE SFP+ | |||||
| S5700-48TP-SI/S5700-48TP-PWR-SI: 48 × 10/100/1000Base-T, 4 of which are dual-purpose 10/100/1000 or SFP | |||||
| S5700-52C-SI/S5700-52C-PWR-SI: 48 × 10/100/1000Base-T | |||||
| EI | S5700-28C-EI/S5700-28C-PWR-EI: 24 × 10/100/1000Base-T | ||||
| S5700-52C-EI/S5700-52C-PWR-EI: 48 × 10/100/1000Base-T | |||||
| S5700-28C-EI-24S: 20 × 100/1000Base-X, 4 × GE Combo | |||||
| S5710-28C-EI/S5710-28C-PWR-EI-AC: 20 x 10/100/1000Base-T, 4 × GE Combo, 4 × 10GE SFP+ | |||||
| S5710-52C-EI/S5710-52C-PWR-EI/S5710-52C-PWR-EI-AC: 48 x 10/100/1000Base-T, 4 × 10GE SFP+ | |||||
| S5720-32P-EI-AC: 24×10/100/1000Base-T(4GE Combo SFP), 4×100/1000Base-X SFP, 4 Gig SFP | |||||
| S5720-52P-EI-AC:48×10/100/1000Base-T, 4 Gig SFP | |||||
| S5720-36C-EI-AC/S5720-36C-PWR-EI-AC: 28×10/100/1000Base-T(4GE Combo SFP), 4×10 GE SFP+ | |||||
| S5720-36C-EI-28S-AC:28×100/1000Base-X SFP(4GE Combo), 4×10GE SFP+ | |||||
| S5720-36PC-EI-AC: 28×10/100/1000Base-T(4GE Combo SFP), 4 Gig SFP | |||||
| S5720-56C-EI-AC/ S5720-56C-PWR-EI-AC:48×10/100/1000Base-T, 4×10GE SFP+ | |||||
| S5720-56C-EI-48S-AC: 48×100/1000Base-X SFP, 4×10GE SFP+ | |||||
| S5720-56PC-EI-AC: 48×10/100/1000Base-T, 4 Gig SFP | |||||
| S5720-32X-EI-AC: 24×10/100/1000 Base-T, 4×100/1000Base-X SFP, 4×10 GE SFP+, 2 QSFP+ | |||||
| S5720-32X-EI-24S-AC: 24×100/1000Base-X SFP, 4×10/100/1000Base-T, 4×10GE SFP+, 2 QSFP+ | |||||
| S5720-50X-EI-AC : 46 ×10/100/1000Base-T, 4×10GE SFP+, 2 QSFP+ | |||||
| S5720-50X-EI-46S-AC: 46 ×10/100/1000Base-X SFP, 4×10GE SFP+, 2 QSFP+ | |||||
| S5720-52X-EI-AC: 48×10/100/1000Base-T, 4×10GE SFP+ | |||||
| HI | S5700-28C-HI: 24 × 10/100/1000Base-T | ||||
| S5700-28C-HI-24S: 24 × 100/1000Base-X | |||||
| S5710-108C-PWR-HI: 48 × 10/100/1000BASE-T, 8 × 10GE SFP+ | |||||
| S5720-32C-HI-24S-AC:24×100/1000Base-X ,8 of which are dual-purpose 10/100/1000 or SFP, 4×10GE SFP+ | |||||
| S5720-56C-HI-AC/S5720-56C-PWR-HI-AC:48×10/100/1000Base-T, 4×10GE SFP+ | |||||
| MAC address table | IEEE 802.1d compliance | ||||
| MAC address learning and aging | |||||
| Static, dynamic, and blackhole MAC address entries | |||||
| Packet filtering based on source MAC addresses | |||||
| MAC address entries: S5700S-LI series: 8K, S5700-LI/S5700-SI series: 16K, S5700-EI series: 32K, S5720-EI series: 64K, S5700-HI series: S5700-HI: 32K, S5710-HI: 456K, S5720-HI: 128K |
|||||
| VLAN | 4K VLANs | ||||
| Guest VLAN and voice VLAN | |||||
| GVRP | |||||
| MUX VLAN | |||||
| VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports | |||||
| 1:1 and N:1 VLAN Mapping | |||||
| SuperVLAN(supported by the S5700-SI/S5700-EI/S5700-HI series) | |||||
| Ring protection | RRPP ring topology and RRPP multi-instance | ||||
| Smart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchover | |||||
| SEP | |||||
| ERPS(G.8032)(supported by the S5700-LI/S5700-SI/S5700-EI/S5700-HI series) | |||||
| STP, RSTP, and MSTP | |||||
| BPDU protection, root protection, and loop protection | |||||
| BPDU Tunnel | |||||
| Reliability | Ethernet OAM (IEEE 802.3ah and 802.1ag) | ||||
| ITU-Y.1731 | |||||
| DLDP | |||||
| LACP | |||||
| E-Trunk(supported by the S5700-SI/S5700-EI/S5700-HI series) | |||||
| BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM (supported by the S5700-EI/S5700-HI series) | |||||
| MPLS features | MPLS L3VPN | ||||
| MPLS L2VPN(VPWS/VPLS) | |||||
| MPLS-TE | |||||
| MPLS QoS | |||||
| Notes: supported by S5710-EI, S5700-HI and S5710-HI | |||||
| IP routing | Static routing | ||||
| RIPv1, RIPv2 and RIPng,ECMP(supported by the S5700-SI/S5700-EI/S5700-HI series) | |||||
| OSPF, OSPFv3, IS-IS, IS-ISv6, BGP and BGP4+ (supported by the S5700-EI/S5700-HI series) | |||||
| IPv6 features | Neighbor Discovery (ND) | ||||
| Path MTU (PMTU) | |||||
| IPv6 ping, IPv6 tracert, and IPv6 Telnet | |||||
| ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type | |||||
| MLD v1/v2 snooping | |||||
| 6to4 tunnel, ISATAP tunnel, and manually configured tunnel(supported by the S5700-SI/S5700-EI/S5700-HI series) | |||||
| Multicast | IGMP v1/v2/v3 snooping and IGMP fast leave | ||||
| Multicast forwarding in a VLAN and multicast replication between VLANs | |||||
| Multicast load balancing among member ports of a trunk | |||||
| Controllable multicast | |||||
| Port-based multicast traffic statistics | |||||
| IGMP v1/v2/v3, PIM-SM, PIM-DM, PIM-SSM, MSDP (supported by the S5700-EI/S5700-HI series) | |||||
| QoS/ACL | Rate limiting on packets sent and received by an interface | ||||
| Packet redirection | |||||
| Port-based traffic policing and two-rate three-color CAR | |||||
| Eight queues on each port | |||||
| WRR, DRR, SP, WRR+SP, and DRR+SP queue scheduling algorithms | |||||
| WRED (supported by the S5710-EI and S5700-HI) | |||||
| Re-marking of the 802.1p priority and DSCP priority | |||||
| Packet filtering at Layers 2 through 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID | |||||
| Rate limiting in each queue and traffic shaping on ports | |||||
| Security | User privilege management and password protection | ||||
| DoS attack defense, ARP attack defense, and ICMP attack defense | |||||
| Binding of the IP address, MAC address, interface, and VLAN | |||||
| Port isolation, port security, and sticky MAC | |||||
| MFF | |||||
| Blackhole MAC address entries | |||||
| Limit on the number of learned MAC addresses | |||||
| 802.1x authentication and limit on the number of users on an interface | |||||
| AAA authentication, RADIUS authentication, HWTACACS authentication, and NAC | |||||
| SSH v2.0 | |||||
| Hypertext Transfer Protocol Secure (HTTPS) | |||||
| CPU defense | |||||
| Blacklist and whitelist | |||||
| Access Security | DHCP Relay, DHCP Server, DHCP Snooping, DHCP Security | ||||
| Management and maintenance | Virtual cable test | ||||
| Port mirroring and RSPAN (remote port mirroring) | |||||
| Remote configuration and maintenance using Telnet | |||||
| SNMP v1/v2/v3 | |||||
| RMON | |||||
| Web NMS | |||||
| HGMP | |||||
| System logs and alarms of different levels | |||||
| 802.3az EEE (supported by the S5700(S)-LI, S5710-EI, S5700-HI and S5710-HI) | |||||
| Dying gasp (supported by the S5700-HI, S5710-HI and S5700(S)-LI(except battery LAN switches) | |||||
| NetStream (supported by the S5710-EI, S5700-HI and S5710-HI) | |||||
| sFlow(supported by the S5700(S)-LI/S5700-EI/S5700-HI series) | |||||
| Interoperability | Supports VBST (Compatible with PVST/PVST+/RPVST) | ||||
| Supports LNP (Similar to DTP) | |||||
| Supports VCMP (Similar to VTP) | |||||
| Operating environment | Operating temperature: 0℃–50℃ | ||||
| Relative humidity: 10%–90% (non-condensing) | |||||
| Input voltage | AC: | ||||
| Rated voltage range: 100 V to 240 V AC, 50/60 Hz | |||||
| Maximum voltage range: 90 V to 264 V AC, 47/63 Hz | |||||
| DC: | |||||
| Rated voltage range: –48 V to –60 V, DC | |||||
| Maximum voltage range: –36 V to –72 V DC | |||||
| Note: PoE-support switches do not use DC power supplies. | |||||
| Dimensions (W x D x H) | S5700-10P-LI-AC:250 x 180 x 43.6 mm | ||||
| S5700-10P-PWR-LI-AC:320 x 220 x 43.6 mm | |||||
| S5700-28P-LI/S5700-28TP-LI-AC/S5700-28X-LI/S5700-28X-LI-24S/S5700-24TP-SI/S5700-28C-HI/S5700-28C-HI-24S/ S5701-28X-LI-AC/ S5701-28X-LI-24S-AC/ S5700-52X-LI-48CS-AC: 442 x 220 x 43.6 mm | |||||
| S5700-28P-PWR-LI/S5700-28TP-PWR-LI-AC/S5701-28TP-PWR-LI-AC/S5700-52P-LI/S5700-52P-PWR-LI/S5700-28X-PWR-LI-AC/S5700-52X-LI/S5700-52X-PWR-LI-AC/ S5700-26X-SI-12S-AC/S5700-28P-LI-BAT/S5700-28P-LI-4AH/S5700-28P-LI-24S-BAT/S5700-28P-LI-24S-4AH: 442 x 310 x 43.6 mm | |||||
| S5710-108C-PWR-HI: 442x470.0x87.2 | |||||
| Others: 442 x 420 x 43.6 mm | |||||
| Powerconsumption | S5700-10P-LI-AC<11.5W | ||||
| S5700-10P-PWR-LI-AC<139W | |||||
| S5700-28P-LI<25W | S5700-24TP-SI<40W | S5700-28C-EI<60W | S5700-28C-HI<76W | ||
| S5700S-28P-LI<25W | S5700-26X-SI-12S-AC<42.3W | S5700-28C-EI-24S<63W | S5700-28C-HI-24S<80W | ||
| S5700-28TP-LI-AC<26.4W | S5700-48TP-SI<64W | S5700-52C-EI<88W | S5710-108C-PWR-HI<1680W (PoE:1440W) | ||
| S5700-28TP-PWR-LI-AC<469.7W(PoE:370W) | S5700-28C-SI<56W | S5710-28C-EI<100W | |||
| S5701-28TP-PWR-LI-AC<238.7W(PoE:185W) | S5700-52C-SI<78W | S5710-52C-EI<165W | S5720-32C-HI-24S-AC<172.7W | ||
| S5700-52P-LI<52W | S5700-24TP-PWR-SI<455W(PoE: 370W) | S5700-28C-PWR-EI<842W (PoE: 740W) | S5720-56C-HI-AC<183.3W | ||
| S5700S-52P-LI<52W | S5700-48TP-PWR-SI<907W (PoE: 740W) |
S5720-56C-PWR-HI-AC: |
|||
| S5700-52C-PWR-EI<930W (PoE: 740W) | |||||
| S5700-28P-PWR-LI<765W (PoE: 740W) | |||||
| S5710-28C-PWR-EI-AC<942W | |||||
| S5710-52C-PWR-EI/S5710-52C-PWR-EI-AC: < 1043W with two 580W AC supplies(PoE:740W), or <1625W with two 1150W AC supplies(PoE:1440W) | |||||
| S5710-28C-PWR-LI<836W (PoE: 740W) | |||||
| S5700-52P-PWR-LI<792W (PoE: 740W) | |||||
| S5710-52C-PWR-LI<917W (PoE: 740W) | |||||
| S5700-28X-LI<42W | |||||
| S5700-28X-LI-24S<54W | |||||
| S5700-28X-PWR-LI-AC <420W | |||||
| S5700-52X-LI<61W | |||||
| S5700-52X-PWR-LI-AC <440 | |||||
| S5700-28P-LI-BAT/S5700-28P-LI-4AH<23W | |||||
| S5700-28P-LI-24S-BAT/S5700-28P-LI-24S-4AH<34.1W | |||||
| S5700-52X-LI-48CS-AC<79.9W | |||||
| S5701-28X-LI-AC <39.5W | |||||
| S5701-28X-LI-24S-AC<60W | |||||
S5700-52C-SI-AC
- Brands Huawei
- Product Code: S5700-52C-SI-AC
- Availability: In Stock
-
$2,136.96
- Ex Tax: $2,136.96
Related Products
S5700-28C-EI Campus Switch
Overview S5700-28C-EI Next-generation energy-saving full GE Layer 3 switches 1. 4*10GE ..
$2,369.74 Ex Tax: $2,369.74
S5700-28C-SI Campus Switch
Overview The Huawei S5700 Series is a flexible platform that lets you optimize L3 switching c..
$1,030.32 Ex Tax: $1,030.32
S5700-28C-EI-24S Campus Switch
Overview S5700-28C-EI-24S Next-generation energy-saving full GE Layer 3 switches 1. 4*1..
$3,434.40 Ex Tax: $3,434.40
S5700-52C-EI without power module
S5700-52C-EI Next-generation energy-saving full GE Layer 3 switches 1. 4*10GE Uplink 2. Intel..
$3,896.14 Ex Tax: $3,896.14
S5710-52C-EI Campus Switch
Overview The Huawei S5700 Series is a flexible platform that lets you optimize L3 switching c..
$6,697.08 Ex Tax: $6,697.08
S5700-52P-LI-AC Campus switch
S5700-52P-LI Next-generation energy-saving full GE Layer 2 switches 1. 48*GE RJ45, 4*GE SFP&nb..
$1,362.31 Ex Tax: $1,362.31
S5700S-52P-LI-AC Campus Switch
Overview 48 Ethernet 10/100/1000 ports,4 Gig SFP,AC 110/220V Similar switch from other vendors..
$1,225.36 Ex Tax: $1,225.36
S5700-52C-PWR-SI
S5700-52C-PWR-SI Next-generation energy-saving full GE Layer 3 switches 1. One extension slot ..
$2,648.30 Ex Tax: $2,648.30
S5700-52X-LI-AC Campus Switch
S5700-52X-LI Next-generation energy-saving full GE switches 1. Advanced Hibernation Management..
$2,014.00 Ex Tax: $2,014.00
S5700-52X-LI-DC Campus Switch
S5700-52X-LI Next-generation energy-saving full GE switches 1. Advanced Hibernation Management..
$3,269.00 Ex Tax: $3,269.00
S5700-28C-EI-AC
Overview S5700-28C-EI Next-generation energy-saving full GE Layer 3 switches 1. 4*10GE ..
$2,556.72 Ex Tax: $2,556.72
S5700-28C-EI-24S-AC
Overview S5700-28C-EI Next-generation energy-saving full GE Layer 3 switches 1. 4*10GE ..
$3,625.20 Ex Tax: $3,625.20
S5700-52C-EI-AC
S5700-52C-EI Next-generation energy-saving full GE Layer 3 switches 1. 4*10GE Uplink 2. Intel..
$4,083.12 Ex Tax: $4,083.12
S5700-28C-SI-AC
Overview The Huawei S5700 Series is a flexible platform that lets you optimize L3 switching c..
$1,221.12 Ex Tax: $1,221.12
Tags: s5700-52c-si, campus, switch, huawei gigabit s5700-52c-si-ac